问题描述
我正在尝试通过C#使用Antimalware Scan Interface (AMSI)。我知道有一些使用AmsiScanBuffer方法的实现,但是我想扫描更大的文件。因此,我想使用amsi.h中定义的IAntimalware COM接口。
到目前为止,我想出了以下代码:
using System;
using System.IO;
using System.Runtime.InteropServices;
using System.Text;
namespace AmsiTest
{
[Guid("82d29c2e-f062-44e6-b5c9-3d9a2f24a2df"),InterfaceType(ComInterfaceType.InterfaceIsIUnkNown),ComImport]
public interface IAntiMalware {
uint Scan([MarshalAs(UnmanagedType.Interface)] IAmsiStream stream,out AMSI_RESULT result,[MarshalAs(UnmanagedType.Interface)] out IAntimalwareProvider provider);
void CloseSession(ulong session);
}
[Guid("b2cabfe3-fe04-42b1-a5df-08d483d4d125"),InterfaceType(ComInterfaceType.InterfaceIsIUnkNown)]
public interface IAntimalwareProvider
{
uint Scan([In,MarshalAs(UnmanagedType.Interface)] IAmsiStream stream,[Out] out AMSI_RESULT result);
void CloseSession(ulong session);
uint displayName(ref IntPtr displayName);
}
[ComImport]
[Guid("fdb00e52-a214-4aa1-8fba-4357bb0072ec")]
[ComSourceInterfaces(typeof(IAntiMalware))]
public class CAntimalware
{
}
public enum AMSI_ATTRIBUTE
{
AMSI_ATTRIBUTE_APP_NAME = 0,AMSI_ATTRIBUTE_CONTENT_NAME = 1,AMSI_ATTRIBUTE_CONTENT_SIZE = 2,AMSI_ATTRIBUTE_CONTENT_ADDRESS = 3,AMSI_ATTRIBUTE_SESSION = 4,AMSI_ATTRIBUTE_REDIRECT_CHAIN_SIZE = 5,AMSI_ATTRIBUTE_REDIRECT_CHAIN_ADDRESS = 6,AMSI_ATTRIBUTE_ALL_SIZE = 7,AMSI_ATTRIBUTE_ALL_ADDRESS = 8,AMSI_ATTRIBUTE_QUIET = 9
}
[Guid("3e47f2e5-81d4-4d3b-897f-545096770373"),InterfaceType(ComInterfaceType.InterfaceIsIUnkNown)]
public interface IAmsiStream
{
uint GetAttribute(AMSI_ATTRIBUTE attribute,uint dataSize,[MarshalAs(UnmanagedType.LPArray,SizeParamIndex = 1)] byte[] data,out int retData);
int Read(
/* [in] */
long position,/* [range][in] */
int size,/* [length_is][size_is][out] */
[MarshalAs(UnmanagedType.LPArray,SizeParamIndex = 1)]
byte[] buffer,/* [out] */
[Out] out int readSize);
}
public class AmsiStream : IAmsiStream
{
private readonly Stream _Input;
public uint GetAttribute(AMSI_ATTRIBUTE attribute,byte[] data,out int retData)
{
const uint E_INSUFFICIENT_BUFFER = 0x8007007A;
retData = 100;
return E_INSUFFICIENT_BUFFER;
}
public int Read(long position,int size,byte[] buffer,out int readSize)
{
_Input.Seek(position,SeekOrigin.Begin);
readSize = _Input.Read(buffer,size);
return 0;
}
public AmsiStream(Stream input)
{
_Input = input ?? throw new ArgumentNullException(nameof(input));
}
}
public enum AMSI_RESULT
{
AMSI_RESULT_CLEAN,AMSI_RESULT_NOT_DETECTED,AMSI_RESULT_BLOCKED_BY_ADMIN_START,AMSI_RESULT_BLOCKED_BY_ADMIN_END,AMSI_RESULT_DETECTED
}
class Program
{
static void Main(string[] args)
{
var scanner = new CAntimalware() as IAntiMalware;
var scanResult = AMSI_RESULT.AMSI_RESULT_BLOCKED_BY_ADMIN_END;
IAntimalwareProvider provider = null;
IAmsiStream stream = new AmsiStream(new MemoryStream(Encoding.ASCII.GetBytes("TestString")));
var result = scanner.Scan(stream,out scanResult,out provider);
}
}
}
运行该程序时,我看到一次GetAttribute
方法被调用(attribute
设置为AMSI_ATTRIBUTE_APP_NAME
,dataSize
设置为1
和{设置为data
Read`方法的{1}}永远不会被调用,但是不管我返回什么,它总是以AccessViolationException结尾(当以64个处理器执行时):
byte[1]'. The
如果我将其作为32位程序运行,则会得到以下信息:
mscorlib.dll!System.StubHelpers.StubHelpers.GetCOMHRExceptionObject(int hr,system.intPtr pCPCMD,object pThis)
[Native to Managed Transition]
ntdll.dll!RtlpFreeHeapInternal()
ntdll.dll!RtlFreeHeap()
mscorlib.ni.dll!00007ff8cad6a76e()
[Managed to Native Transition]
ConsoleApp6.exe!AmsiTest.Program.Main(string[] args) Line 109
at c:\temp\ConsoleApp6\Program.cs(109)
[Native to Managed Transition]
mscoreei.dll!00007ff8cfb78c01()
mscoree.dll!00007ff8d684ac42()
kernel32.dll!00007ff8e4416fd4()
ntdll.dll!RtlUserThreadStart()
据此,我认为我的COM声明有些错误,但是我无法弄清楚。我还尝试将System.ArgumentException: 'Value does not fall within the expected range.'
ConsoleApp6.exe!AmsiTest.Program.Main(string[] args) Line 109
at c:\temp\ConsoleApp6\Program.cs(109)
[Native to Managed Transition]
mscoreei.dll!__CorExeMain@0()
mscoree.dll!_ShellShim__CorExeMain@0()
mscoree.dll!__CorExeMain_Exported@0()
ntdll.dll!773974b4()
声明替换为byte[] data
,但无济于事。
有什么想法我在这里做错了吗?
这些是amsi.idl文件中的声明:
IntPtr
解决方法
您需要告诉.NET,数组是IAnsiStream中的Out参数,如下所示:
[Guid("3e47f2e5-81d4-4d3b-897f-545096770373"),InterfaceType(ComInterfaceType.InterfaceIsIUnknown)]
public interface IAmsiStream
{
[PreserveSig]
int GetAttribute(AMSI_ATTRIBUTE attribute,int dataSize,[Out,MarshalAs(UnmanagedType.LPArray,SizeParamIndex = 1)] byte[] data,out int retData);
[PreserveSig]
int Read(long position,int size,SizeParamIndex = 1)] byte[] buffer,out int readSize);
}
还请注意,我使用PreserveSig来将方法的返回值明确定义为HRESULT。
这是GetAttribute方法的示例实现:
public int GetAttribute(AMSI_ATTRIBUTE attribute,byte[] data,out int retData)
{
const int E_NOT_SUFFICIENT_BUFFER = unchecked((int)0x8007007A);
switch (attribute)
{
case AMSI_ATTRIBUTE.AMSI_ATTRIBUTE_APP_NAME:
const string appName = "My App Name";
var bytes = Encoding.Unicode.GetBytes(appName + "\0"); // force terminating zero
retData = bytes.Length;
if (dataSize < bytes.Length)
return E_NOT_SUFFICIENT_BUFFER;
Array.Copy(bytes,data,bytes.Length);
return 0;
// TODO: implement what's needed
default:
retData = 0;
const int E_NOTIMPL = unchecked((int)0x80004001);
return E_NOTIMPL;
}
}