问题描述
我使用Modelica在ANSYS Twin Builder中编写了一个代码。它引发了一个错误:“调用函数Medium.density():只能调用具有一个算法部分或外部函数规范的函数”您能帮我为什么会出现此错误吗?谢谢。
//Component(s)
Real f[2*T_per/(T_per/10)];
Real time_interval;
parameter Real opening_HP;
Real opening_NP;
parameter Real N;
parameter Real T_per;
parameter Real V_tod;
parameter Real V_unten;
Modelica.Fluid.Valves.ValveIncompressible NP (
dp_nominal = 65.21,opening = opening_NP,rho_nominal = 998.388,Kv = 0.02178066,V_flow(start = 0.0000488573),dp = dp(start = 65.211094),m_flow(start = 0.048778537));
Modelica.Fluid.Valves.ValveIncompressible HP (
Kv = 0.021549519,opening=opening_HP,dp_nominal = 66.6175,rho_nominal = 1019.921,V_flow(start = 0.0000478258),dp(start = 66.6175),m_flow(start = 0.048778537));
Modelica.Fluid.Machines.SweptVolume Swept1 (pistonCrossArea = 0.0001131,clearance = 0.000002,portsData = false);
Modelica.Fluid.Vessels.OpenTank tank (vessel_ps_static = 400000);
Modelica.Fluid.Vessels.OpenTank tank1 (vessel_ps_static = 50000000);
equation
T_per=pi/(180*3600*N/60);//Radian
time_interval=T_per/10;
for i in 1:2*T_per/(T_per/10) loop
f[i]=((V_unten_V_tod)/2)*sin((2*pi*i*time_interval/T_per)+(V_tod+(V_unten-V_tod)/2));
end for;
if der(f)>=0 then
opening_NP=1;
opening_HP=0;
else
opening_NP=0;
opening_HP=1;
end if;
//Connection(s)
connect(NP.port_a,Swept1.ports[1]);
connect(HP.port_b,Swept1.ports[2]);
connect(HP.opening,tank1.ports[1]);
connect(NP.opening,tank.ports[1]);
end Hochdruckreiniger2;
解决方法
似乎您没有选择流体模型的介质,在Modelica中,您通常可以通过如下修改来做到这一点:
Modelica.Fluid.Valves.ValveIncompressible NP (
redeclare package Medium=Modelica.Media.Water.IdealSteam,...
(用于NP,HP,坦克和坦克1。)
没有Medium是PartialMedium的情况,其中Medium.density是既没有算法也没有外部调用的部分函数。
请注意,其他工具将以各种其他方式检测到此错误,并且从Modelica 3.3开始,从技术上讲,既不使用算法也不进行外部调用的函数是合法的(前提是输出变量具有声明分配-在这种情况下是不指定的)。
另外,dp=dp(start=...)
应该只是dp(start=...)
,而vessel_ps_static
不应这样更改。