问题描述
我正在尝试创建这个基本的 clock_nanosleep
示例,但它不会暂停我不断打印数字的 for
循环。如果我取消对 //t.tv_nsec = s/1000000000;
的注释,将不会打印任何内容,但会运行 for
循环。
// POSIX.1-2017 is what compiler is confined to.
#define _XOPEN_SOURCE 700
// C headers.
#include <stdint.h>
#include <time.h>
#include <stdio.h>
int main(int argc,char *argv[])
{
// Counter.
uint8_t i;
// Time.
int s = 1;
// Create a timespec structure and calculate it's members.
struct timespec t;
t.tv_sec = s;
//t.tv_nsec = s/1000000000;
// Set flags i.e. TIMER_ABSTIME to 0 to use relative instead of absolute time.
int flags = 0;
// Choose the clock i.e. CLOCK_MONOTONIC is a "clock_id" for the clock started at system start.
int clock_id = CLOCK_MONOTONIC;
for(i = 0; i < 256; i++){
printf("%d",i);
// Because last argument is NULL in case of error,remaining time is not stored in "t".
clock_nanosleep(clock_id,flags,&t,NULL);
}
return 0;
}
我完全不知道为什么这不起作用。 POSIX 声明:
int clock_nanosleep(clockid_t clock_id,int flags,const struct timespec *rqtp,struct timespec *rmtp);
如果标志中没有设置标志 TIMER_ABSTIME
参数,clock_nanosleep()
函数将导致当前
线程暂停执行,直到时间间隔
rqtp
参数指定的时间已过,或者信号已传递
到调用线程,它的动作是调用一个信号捕获
函数,否则进程终止。
我确保标志已清零。我设置了 rqtp
,即 &t
。
用于测量的时钟
时间应为 clock_id
指定的时钟。
我确实使用了 CLOCK_MONOTONIC
。
如果 clock_nanosleep()
函数返回,因为它已经
被信号中断,返回相应的错误
价值。对于相对 clock_nanosleep()
函数,如果 rmtp
参数是非 NULL
,它引用的 timespec 结构应该是
更新以包含间隔中剩余的时间量(
请求的时间减去实际睡觉的时间)。 rqtp
和 rmtp
参数可以指向同一个对象。如果 rmtp
参数是 NULL
,
剩余时间不返还。绝对clock_nanosleep()
函数对 rmtp
引用的结构没有影响。
我还将最后一个参数设置为 NULL
,以便在 clock_naanosleep()
被任何信号中断时不存储剩余时间。
那么为什么这不起作用?
解决方法
在这种情况下,您应该始终检查实际的返回值是什么,在这种情况下将是 EINVAL
,因为 t.tv.nsec
未初始化。
使用:
struct timespec t = {
.tv_sec = s,};
正确初始化所有字段,即使是您不打算使用的字段。
,局部变量不会被隐式初始化。因此,如果您不设置 t.tv_nsec
,它可以包含任何值。如果该值恰好在 0 - 999999999 的范围之外,则 clock_nanosleep
将立即返回错误代码。
当您设置 t.tv_nsec
时看不到任何输出的原因是因为您的打印方式:
printf("%d",i);
您没有在输出中包含换行符。 stdout
流是行缓冲的,因此它不会自动将输出流刷新到控制台。将 \n
添加到格式字符串的末尾,您将看到打印出来的行。